MASTER FEED SECTION
SM 3-57 C262/C265
Replacement
Adjustment
3.7.22 MASTER FEED MYLAR POSITIONING
NG OK
PURPOSE:
These strips of mylar are easily put in the wrong position. Take care
to set these properly to avoid master jams.
PROCEDURE:
When replacing or removing the thermal head, the cutter unit, the master duct, or
the guide plate of the lower master feed control roller, install the lower tension roller
or lower master feed control roller as shown in the illustration.
C262R901.WMF
C262R902.WMF
C262R903.WMF
C262R904.WMF
Thermal Head Base
Before the tension roller
Lower Master Feed Control Roller
Exit Guide Plate
Buffer Duct Entrance Plate
Before the Master Feed Control Roller
O