DIP SW, LED, VR, TP, AND FUSE TABLES 
SM 4-23 C262/C265 
Trouble-
shooting 
 
4.5.4 LED'S 
MPU 
Number Function 
LED1 
Monitors the RAM and SARM operation on the CPU. This LED is lit if there is a 
problem. 
LED2  Monitors the CPU operation. Usually, this LED is blinking. 
 
I/O Board 
Number Function 
LED1  Monitors the CPU operation. Usually, this LED is blinking. 
 
ACU 
Number Function 
LED1  Monitors the CPU operation. Usually, this LED is blinking. 
 
Operation Panel 
Number Function 
LED101  This LED is blinking in normal operation 
During firmware download: quick blink 
After firmware download: slow blink 
LED102  During firmware download: quick blink 
After firmware download: slow blink 
NOTE:  The Green LED of the start button on the operation panel displays the 
status of firmware downloading in normal; therefore, it is not necessary to 
open the operation panel. 
 
4.5.5 FUSES 
Power Supply Unit 
Fuse Rated Current  Protect 
F700  10A  Power Supply Unit 
F701/ 
F702 
6.3A x 2  I/O Board 
F703/ 
F704 
6.3A x 2  Main Motor Drive Board 
F705 2A Not used 
 
NOTE:  F701 and F702, F703 and F704 are connected in parallel to protect the 
board. If one fuse is broken, the machine works if the other fuse does not 
break. But replace the broken fuse as soon as possible.