COPY IMAGE ADJUSTMENT
   
SM 3-15 C262/C265 
Replacement 
Adjustment 
3.4.3  VERTICAL MAGNIFICATION ADJUSTMENT 
Purpose: To adjust the vertical magnification to within the adjustment standard by 
changing the master writing speed. 
 
Adjustment standard: Within 100 ± 1.0% 
 
CAUTION: This adjustment is required every time the ECU is replaced. 
 
1.  Turn on the main switch, access SP8-005-1 (TH Test Patterns), and print 
pattern number 6. 
2.  On the printout, measure the distance of 15 intervals in the sub-scan direction, 
as shown in the diagram. 
 
3.  The distance should be 122 mm. If it is not 122 mm, calculate the necessary 
adjustment with the following formula. 
[(122 - measured value) / 122] x 100 = x.x % 
4.  Access SP6-001-7 (Master writing speed) and adjust the value (x.x %). 
5.  Access SP8-005-1 (TH Test Patterns) and print pattern number 6. 
6.  Check the distance of 15 intervals in the sub-scan direction again, to ensure it 
is within specifications 
NOTE:  The image scanning speed can be adjusted with SP6-001-5, -6 (Scanning 
speed). If you change the speed with this SP, the vertical magnification 
also changes. Normally, do not use this SP mode to adjust the vertical 
magnification. 
 
C262R209.WMF 
122mm 
Sub-scan 
direction