SERVICE PROGRAM MODE
C262/C265 5-34 SM
6. System Adjustment
No. Display No. Menu Function Default Setting
1
Main Scan Position
- Platen
0 -5.0 to 2.0 mm
2
Main Scan Position
- DF
Side-to-side registration
adjustment; see Note 1.
0 -5.0 to 5.0 mm
3
Scan Start Position -
Platen
0 -2.0 to 5.0 mm
4
Scan Start Position -
DF
Scanning start line
adjustment; see Note 2.
0 -5.0 to 5.0 mm
5
Scanning Speed -
Platen
0 -5.0 to 5.0%
6
Scanning Speed -
DF
See Note 3.
0 -5.0 to 5.0%
7
Master Writing
Speed
See Note 4. 0 -5.0 to 5.0%
8
Master Writing
Length
Do not use in the field. 0 -5.0 to 5.0%
9
Main Master Writing
Position
0 -3.0 to 3.0 mm
6-1
Scan &
Writing
Adjustment
10
Trail Edge Margin
0 0 to 2mm
1
Letter
1 0 to 2
2
Letter/Photo
1 0 to 2
3
Photo
1 0 to 2
4
Pencil
1 0 to 2
6-2
Master
Making
Density
5
Tint
See Note 5.
1 0 to 2
6-3
Drum
Master
Clamp
1
Drum Master Clamp
Registration
See Note 6. 0 -10 to 10 mm
1
Master Eject
Sensor
2.5 1.5 to 3.0 V
2
Master End Sensor
0.8 0.1 to 3.0V
3
Master Edge
Sensor - High
2 1.5 to 3.0 V
4
Master Set Sensor
2.8 1.5 to 3.0 V
5
Drum master 1st
sensor
2.5 1.5 to 3.0 V
6
Drum master 2nd
sensor
The use of these SP
modes is explained in
various parts of the
Replacement and
Adjustment section.
2.5 1.5 to 3.0 V
6-4
Sensor
Voltages/
Thresholds
7
List of Sensors
Adjustment
See Note 7
1
SBU Auto
Adjustment
Refer to the
Replacements and
Adjustments section.
-
2
SBU Gain - EVEN
Do not adjust. -
3
SBU Gain - ODD
Do not adjust. -
4
SBU DC Count -
EVEN
Do not adjust. -
6-5
Sensor
Board Unit
5
SBU DC Count -
ODD