MASTER FEED
C262/C265 6-54 SM
Misfed Master Detection
If the master buffer duct is blocked by a broken piece of master, suction from the
fans may be insufficient. To prevent this, if the master duct sensor [A] detects a
master when there should be none there, the machine detects that there is a
broken piece of master in the duct, and a caution is shown on the display.
Opening the Door for Misfed Master Removal
If pieces of the master remain in the master buffer duct, open the door [B] to
remove them. Normally, pieces of master do not remain in the duct. Therefore, the
door is only for emergency cases.
Also there is a jam removal dial to manually rotate the master feed rollers.