MASTER EJECT
C262/C265 6-34 SM
Homing Operation
At power on or when recovering from an error or jam condition, the machine carries
out the pressure plate homing operation.
If certain errors occur, the pressure plate may not be in the home position. The
homing operation starts by turning the pressure plate toward the drum and then it
returns to the home position.
The homing operation is as follows:
1. The pressure plate turns clockwise (as seen from the operation side) until both
the pressure plate HP sensor [A] and the limit position sensor [B] are actuated.
C262D023.WMF
C262D024.WMF
Master Eject
Ready Position
[A]
[B]
Passed the home
position slightly
Passed the home
position slightly
[A]
[B]
Home Position