MAINTENANCE TABLE
SM 2-1 C262/C265
Preventive
Maintenance
2. PREVENTIVE MAINTENANCE
2.1 MAINTENANCE TABLE
The following items must be maintained periodically.
Symbol key: C: Clean, R: Replace, L: Lubricate, A: Adjust
WARNING
Turn off the main power switch and disconnect the machine before you do
any procedure in this section.
INTERVAL
ITEM
EVERY
600K
EVERY
1200K
EVERY
2400K
EVERY
3000K
LIFE
WHEN
VISIT
NOTE
Scanner/Optics
Exposure Glass
C Damp Cloth
Master Making Unit
Thermal Head C R C Damp Cloth (Alcohol)
Expected Life: 30K masters
Platen Roller C C Damp Cloth (Alcohol)
Expected Life: 30K masters
Cutter Unit R Damp Cloth (Alcohol)
Expected Life: 30K masters
Master Feed Control
Roller
R Expected Life: 30K masters
Platen Roller R Expected Life: 30K masters
Paper Feed
Paper Pick-up Roller R C Damp Cloth (Alcohol)
Paper Feed Roller R C Damp Cloth (Alcohol)
Friction Pads R C Damp Cloth (Alcohol)
Registration Roller C Damp Cloth (Alcohol)
Paper End Sensor C Dry Cloth
Paper Length Sensor C Dry Cloth
Paper Pick-up Roller
Bushing
L
Motor Oil (SAE #20)
Paper Feed Roller
Bushing
L
Motor Oil (SAE #20)
Paper Exit Pawl Drive
Gear
L
Lubricate the shaft with
Alvania #2 ( 3.12.6.)
Main Drive Unit R
Expected Life: 7500K prints
( 3.11.2.)
Image Shifting Gear
L
Lubricate the surface of the
gear with Alvania #2 (
3.11.6.)
Double Feed Sensor C Dry Cloth