MASTER EJECT
C262/C265 6-36 SM
Ejected Master Compression
When the ejected master has been fed to the master eject box, the pressure plate
compresses the master. During this operation, the machine can recognize how full
the eject box is by monitoring the lower limit and home position sensors.
When there are no or very few masters in the box
If there are no or only a few masters in the box, the pressure plate can move to its
lowest position. The pressure plate limit position sensor detects this position.
The pressure plate turns counterclockwise from the master eject ready position
until the limit position sensor [B] has been actuated twice. The sensor status
changes: on ⇒ off ⇒ on.
The pressure plate stays at the lower limit position for 2 seconds, then returns to
the home position.
C262D026.WMF
Lower Limit Position
[A]