MASTER EJECT
SM 6-37 C262/C265
Detailed
Descriptions
When there are a lot of masters
If there are a lot of used masters in the box, the pressure plate cannot move to the
lower limit position.
If the lower limit position sensor [B] is not actuated within 7 seconds after the
pressure plate starts traveling from the master eject ready position, the pressure
plate motor stops.
The pressure plate stays in the same position for 2 seconds to compress the
masters. Then, it returns to the home position.
There is a torque limiter [C] built into the gear. When the built-up masters in the box
block pressure plate movement, the torque limiter allows this gear to slip.
C262D027.WMF
Master Compression
Position