SERVICE CALL CODE TABLE
C262/C265 4-6 SM
Code Title Conditions Possible Causes
SC506
Wing guide motor
lock (Wing lower
position error)
When the wing guide moves
upwards, the sensor is not de-
activated for more than 6 seconds
after the wing guide motor on
signal is generated.
When the wing guide moves
downwards, the sensor is not
activated for more than 6 seconds
after the wing guide motor on
signal is generated.
Defective sensor
Defective motor
Defective wing guide
Overrunning of the
sensor slit
SC507
Wing guide motor
lock (Wing Upper
position error)
When the wing guide moves
upwards, the sensor is not
activated for more than 6 seconds
after the wing guide motor on
signal is generated.
When the wing guide moves
downwards, the sensor is not de-
activated for more than 6 seconds
after the wing guide motor on
signal is generated.
Defective sensor
Defective motor
Defective wing guide
SC508
Slider lift motor
lock (paper
sensor)
When the slider moves downwards,
the sensor is not activated for more
than 7 seconds after the slider lift
motor on signal is generated.
When the slider moves upwards,
the sensor is not de-activated for
more than 9 seconds after the
slider lift motor on signal is
generated.
Defective sensor
Defective motor
Defective ECU baord
Motor belt has come off
SC509
Slider lift motor
lock (Slider upper
limit sensor)
When the slider moves upwards,
the sensor is not activated for more
than 9 seconds after the slider lift
motor on signal is generated.
When the slider moves downwards,
the sensor is not de-activated for
more than 9 seconds after the
slider lift motor on signal is
generated.
Defective sensor
Defective motor
Defective ECU board
Mechanism blocked by
foreign material
SC510
Job Separator
motor lock (Slider
HP sensor)
When the slider moves toward the
delivery table, the sensor is not de-
activated for more than 5 seconds
after the job separator motor on
signal is generated.
Defective sensor
Defective motor
Defective ECU board
Mechanism blocked by
foreign material
SC511
Job Separator
motor lock (Slider
position sensor)
When the slider returns, the sensor
signal does not change status for
more than 5 seconds after the job
separator motor on signal is
generated.
Defective sensor
Defective motor
Defective ECU board
Mechanism blocked by
foreign material
The cover pad over-runs
its correct position

Table of Contents