INSTALLATION PROCEDURE
SM 1-21 C262/C265
Installation
3. Place the DF exposure glass [A] on the glass holder.
NOTE: When installing the DF exposure glass, make sure that the white dot
[B] is positioned at the front side, as shown.
4. Peel off the backing [C] of the double-sided tape attached to the rear side of the
scale guide [D], then install the scale guide (2 screws removed in step 2).
5. Install the two stud screws [E].
6. Mount the DF by aligning the holes [F] in the DF with the stud screws, then
slide the DF to the front as shown.
7. Secure the DF unit with two screws [G].
8. Connect the cables [H] and cable [I] to the main body.
C262I048.WMFF
[A]
[B]
[C]
[D]
[E][F] [G]
[H]