SCANNER UNIT
SM 3-11 C262/C265
Replacement
Adjustment
8. Secure the 1
ST
scanner with the pins [E].
9. Install the tension spring [F] on the tension bracket.
10. Tighten the tension bracket [G].
11. Secure the scanner drive pulley [H] (1 Allen screw).
12. Remove the scanner positioning pins [I] (P/N: A0069104).
13. Slide the scanner to the left and right several times, then set the scanner
positioning pins to check the clamp position and wire tension bracket position
again.
C262R012.WMF
C262R013.WMF
[E]
[I]
[I]
[F]
[G]
[H]