Instrument Function
R&S
®
SMBV100A
330Operating Manual 1407.6062.32 ─ 08
When intending to work with an external clock source, the frequency to be applied must
be entered here.
SCPI command:
[:SOURce<hw>]:BB:ARB:CLOCk on page 506
Trigger/Marker
Calls the Trigger and Marker menu.
This menu is used to select the trigger source, set the time delay on an external trigger
signal and configure the marker output signals (see "Trigger/Marker/Clock Set-
tings" on page 331).
SCPI command:
n.a.
Execute Trigger
Executes trigger manually. A manual trigger can be executed only when an internal trig-
ger source and a trigger mode other than Auto are selected.
SCPI command:
[:SOURce<hw>]:BB:ARB:TRIGger:EXECute on page 509
Clock
Calls the "Clock" menu. The "Clock" menu is used to select the clock source (see "Clock
Settings" on page 343).
SCPI command:
n.a.
Create Test Signal...
Selects the form of the test signal and calls the menu for generating it. A sinusoidal,
rectangular or test signal with constant I/Q can be selected.
See the corresponding section for detailed description of the parameters for the selected
test signal:
● "Sine Test Signals" on page 345
● "Rect Test Signal" on page 346
● "Const IQ Test Signal" on page 347
SCPI command:
n.a.
Multi Segment
Calls the menu for calculating multi segment waveforms (see chapter 5.8.4.2, "Multi
Segment Waveforms", on page 348).
SCPI command:
n.a.
Multi Carrier
Calls the menu for calculating multi carrier waveforms (see chapter 5.8.4.3, "Multi Carrier
Waveforms", on page 359).
SCPI command:
n.a.
Baseband Signal - Baseband Block