Remote Control Commands
R&S
®
SMBV100A
685Operating Manual 1407.6062.32 ─ 08
[:SOURce<hw>]:PULM:DOUBle:STATe...........................................................................686
[:SOURce<hw>]:PULM:DOUBle:WIDTh...........................................................................686
[:SOURce<hw>]:PULM:MODE........................................................................................686
[:SOURce<hw>]:PULM:OUTPut:SYNC[:STATe]................................................................686
[:SOURce<hw>]:PULM:PERiod.......................................................................................687
[:SOURce<hw>]:PULM:POLarity.....................................................................................687
[:SOURce<hw>]:PULM:SOURce.....................................................................................688
[:SOURce<hw>]:PULM:STATe........................................................................................688
[:SOURce<hw>]:PULM:TRIGger:EXTernal:GATE:POLarity................................................688
[:SOURce<hw>]:PULM:TRIGger:EXTernal:IMPedance......................................................689
[:SOURce<hw>]:PULM:TRIGger:EXTernal:SLOPe............................................................689
[:SOURce<hw>]:PULM:TRIGger:MODE...........................................................................689
[:SOURce<hw>]:PULM:WIDTh........................................................................................690
[:SOURce<hw>]:PULM:DELay <Delay>
The command sets the pulse delay. The pulse delay determines the time that elapses
after a trigger event before pulse modulation starts. The pulse delay is not effective for
double pulse generation.
Parameters:
<Delay> float
Range: 0 to 100 s
Increment: 10 ns
*RST: 10 ns
Default unit: ns
Example:
PULM:DEL 13 us
13 us elapse after a trigger before the first pulse is generated.
Options: R&S SMBV-K23 (Pulse Generator)
[:SOURce<hw>]:PULM:DOUBle:DELay <Delay>
The command sets the delay from the start of the first pulse to the start of the second
pulse.
Parameters:
<Delay> float
Range: 20 ns to 100 s
Increment: 10 ns
*RST: 3 us
Default unit: ns
Example:
PULM:DOUB:DEL 22 us
22 us elapse between the beginning of the first pulse and the
beginning of the second pulse in double-pulse mode.
Options:
R&S SMBV-K23 (Pulse Generator)
SOURce Subsystem