EasyManua.ls Logo

Rohde & Schwarz SMBV100A - Page 702

Rohde & Schwarz SMBV100A
780 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100A
685Operating Manual 1407.6062.32 ─ 08
[:SOURce<hw>]:PULM:DOUBle:STATe...........................................................................686
[:SOURce<hw>]:PULM:DOUBle:WIDTh...........................................................................686
[:SOURce<hw>]:PULM:MODE........................................................................................686
[:SOURce<hw>]:PULM:OUTPut:SYNC[:STATe]................................................................686
[:SOURce<hw>]:PULM:PERiod.......................................................................................687
[:SOURce<hw>]:PULM:POLarity.....................................................................................687
[:SOURce<hw>]:PULM:SOURce.....................................................................................688
[:SOURce<hw>]:PULM:STATe........................................................................................688
[:SOURce<hw>]:PULM:TRIGger:EXTernal:GATE:POLarity................................................688
[:SOURce<hw>]:PULM:TRIGger:EXTernal:IMPedance......................................................689
[:SOURce<hw>]:PULM:TRIGger:EXTernal:SLOPe............................................................689
[:SOURce<hw>]:PULM:TRIGger:MODE...........................................................................689
[:SOURce<hw>]:PULM:WIDTh........................................................................................690
[:SOURce<hw>]:PULM:DELay <Delay>
The command sets the pulse delay. The pulse delay determines the time that elapses
after a trigger event before pulse modulation starts. The pulse delay is not effective for
double pulse generation.
Parameters:
<Delay> float
Range: 0 to 100 s
Increment: 10 ns
*RST: 10 ns
Default unit: ns
Example:
PULM:DEL 13 us
13 us elapse after a trigger before the first pulse is generated.
Options: R&S SMBV-K23 (Pulse Generator)
[:SOURce<hw>]:PULM:DOUBle:DELay <Delay>
The command sets the delay from the start of the first pulse to the start of the second
pulse.
Parameters:
<Delay> float
Range: 20 ns to 100 s
Increment: 10 ns
*RST: 3 us
Default unit: ns
Example:
PULM:DOUB:DEL 22 us
22 us elapse between the beginning of the first pulse and the
beginning of the second pulse in double-pulse mode.
Options:
R&S SMBV-K23 (Pulse Generator)
SOURce Subsystem

Table of Contents

Other manuals for Rohde & Schwarz SMBV100A

Related product manuals