3 - TECHNICAL SPECIFICATIONS
EN
Pag. 16/22 - Cap. 3 THIS MANUAL IS PROPERTY OF SCM INDUSTRIA S.P.A - ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN
Cutterblock with throw-away knives
Surface planning
(
according to norm EN 859:2007+ A1:2009)*
Operating conditions
Thicknessing machine
(
according to norm EN 860:2007+ A1:2009)*
Measured size description
Reference
norm
Uncertainity
K
Surface planning
Thicknessing
machine
Operator
station
VSA LAV VSA
LAV
INPUT 82
93
[111]
77
92
[107]
Lop: sound
pressure level
at operator
station dB (A)
and peak level
[dB(C)]
OUTPUT
EN ISO
11202:2010
4 dB
74
87
[105]
Lw: sound power level
dB (A)
re 1pW
EN ISO
3744:2010
2 dB 88 102 86 101
The maximum istantaneus noise level pressure is under 130 dB (C).
VSA: Idle working without suction LAV: In operation
* Refer to the test document N° 2015029 to analyse the actual operating conditions used to make the test,