System Programming Codes (Expert Mode Codes) Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
A-22 HiPath 3000/5000 V9, Service documentation
pcodes.fm
Accessing system administration
27 Sensors (HiPath 3550/HiPath 3350/HiPath 3500/HiPath 3300 only)
27 1 Sensor type: 0 = Alarm, 1 = Call distribution
27 2 Destination station no.; select sensor 1 - 4
External station with seizure code (trunk/direction)
Internal station with station prefix (if programmed)
27 3 Station no. for announ.; select sensor 1 - 4 and enter station or group
number (max. 6 digits)
27 4 Infobox control data; select sensor 1 - 4 and enter control characters 0 -
9, *, #, max. 24 digits
27 5 Call duration; select sensor 1 through 4 and enter 1 to 255
27 6 Call pause; select sensor 1 through 4 and enter 0 to 255
27 7 Number of rings; select sensor 1 through 4 and enter 1 to 255
27 8 Block time; select sensor 1 through 4 and enter 0 to 255
27 9 Sensor text; select sensor 1 to 4, enter text containing up 16 characters
(alphanumeric)
1
28 Edit CDB
28 1 Print CDB data
28 2 Save CDB data
28 2 1 CDB to MMC
28 2 2 CDB from MMC
29 System details
29 1 System
29 1 1 System type (for verification purposes only)
29 1 2 SWversion (for verification purposes only)
29 2 Status display
29 2 1 Call forwarding, external, 0 = Off, 1 = On (for verification purposes only)
29 2 2 Night service, 0 = Off, 1 = On (for verification purposes only)
29 2 3 Trunk, 0 = Inactive, 1 = Active (for verification purposes only)
29 2 4 Ping, 1 = IP address, 2 = Start
29 2 5 MAC address
29 3 Options (HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 only)
Table A-3 Expert Mode Codes
Code Function