power_calc.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
D-7
Nur für den internen Gebrauch Identifying System Power Requirements
HiPath 3350 Board Power Requirement
SLU8 S30817-Q922-A301 0.8 –
STLS2 S30817-Q924-B313 0.6 –
STLS4 S30817-Q924-A313 1.0 –
STRB S30817-Q932-A 0.5 –
TLA2 S30817-Q923-Bxxx 0.1 –
TLA4 S30817-Q923-Axxx 0.2 –
TLA8 S30817-Q926-Axxx 0.4 –
TMGL4 S30810-Q2918-X 4.7
2
0.1
2
TMQ4 S30810-Q2917-X 3.8 –
V24/1 S30807-Q6916-X100 0.3 –
4SLA S30810-Q2923-X200 0.7 0.7
8SLA S30810-Q2923-X100 1.3 1.3
16SLA S30810-Q2923-X 2.5 2.5
1 For each active (off hook) station, the net resource requirement increases by approximately 1.6W (dependent on the tele-
phone’s line length and DC resistance).
2 Identified at a traffic flow of 0.8 Erlang
Table D-6 HiPath 3350 Board Power Requirement
Board or Component Part Number Net Power Requirement in
W
5 V –48 V