Boards for HiPath 3000 Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-148 HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
Base station power supply via two U
P0/E
interfaces
Connect the base station to two free interfaces on SLC16N as shown in Figure 3-54. Be careful
not to exceed the maximum connection cable lengths (1000 m for 2 x 0.6 mm).
Using two U
P0/E
interfaces increases the traffic capacity in BS3/3 base stations.
Figure 3-54 Base Station Power Supply via Two U
P0/E
Interfaces (not for U.S.)
a
b
1
CABLU
MDFU, MDFU-E
2
3
4
5
U
P0/E
1
U
P0/E
2
BS3/3 for in-
doors
Splitting
strip
HiPath 3550
SLC16N

Table of Contents