Analog Modules
4-172
Programmable Logic Controllers S7-300 Module Data
A5E00105505-03
Status, interrupts, diagnostics
Interrupts
Diagnostic interrupt Programmable
Diagnostic functions Programmable
Group error display Red LED (SF)
Diagnostic information
readable
Possible
Substitute value can be applied Yes, programmable
Data for Selecting an Actuator
Output ranges (rated values)
Voltage ±10 V
0 to 10 V
1 to 5 V
Current ±20 mA
0 to 20 mA
4 to 20 mA
Load resistance (in the nominal
range of the output)
For voltage outputs
capacitive load
min. 1 k
max. 1 µF
For current outputs
Inductive load
max. 500
max. 1 mH
Voltage outputs
Short-circuit protection
Short-circuit current
Yes
max. 40 mA
Current outputs
No-load voltage max. 18 V
Destruction limit against
voltages/currents applied from
outside
Voltage at outputs to M
ANA
max. 15 V continuous
75 VDC for no more than
0.1 s
(pulse duty factor 1 : 20)
Current max. 50 mA DC
Connection of actuators
For voltage output
Four-conductor
connection (measuring
circuit)
Possible
For current output
Two-conductor
connection
Possible
4.27.1 Synchronicity
Characteristics
Reproducible (i.e. same length) reaction times are achieved with the SIMATIC with
an equidistant DP bus cycle and the synchronization of the following free running
single cycles:
Free running of the user program. The length of the cycle time can vary due to
acyclic program branching.
Free running, variable DP cycle at the PROFIBUS subnetwork
Free running cycle at the DP-Slave back plane bus.
Free running cycle during the signal conditioning and conversion in the
electronic modules of the DP-Slave.
In the case of equidistance the DP cycle runs in phase and with the same length.
In this cycle the processing levels of a CPU (OB 61 to OB 64) and the
synchronous peripheral are synchronized. The I/O data are therefore transferred at
defined and consistent time intervals (clock synchronicity).
Requirements
The DP-Master and DP-Slave must support the synchronicity. They require
STEP 7 from Version 5.2.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)