Index-1
Programmable Logic Controllers S7-300 Module Data
A5E00105505-03
Index
Numbers
2-wire transmitters, 4-52
A
Absolute value encoder (SSI), SM 338;
POS-INPUT, 5-14
Accessories, D-1
Active bus module, dimension drawing, C-8
Actuator connection, to analog output module,
4-66
Address, Glossary-1
Addressing, SM 338; POS-INPUT, 5-15
Aggregate current, Glossary-1
Ambient conditions
mechanical, 1-10, 1-16
SIPLUS S7-300-modules, 1-16
Analog functions, STEP 7 blocks, 4-1
Analog Input Module, SM 331; AI 8 x 13 bits,
4-108
Analog input module
common-mode error, 4-73
configuring error, 4-73
connecting resistance thermometers, 4-53
connecting resistors, 4-53
connecting sensor, 4-45
connecting thermocouple, 4-58
diagnostic interrupt, 4-40
diagnostic message in measured value,
4-72
diagnostics, 4-40
group diagnostics, 4-40
interference frequency suppression, 4-42,
A-9
isolated, 4-45
limit value, 4-40
load voltage missing, 4-73
measurement, 4-41
measuring method, 4-41
measuring methods and measuring ranges,
A-9
measuring range, 4-41
module filtering mode, 4-41
non-isolated, 4-45
Overflow, 4-74
parameter assignment error, 4-73
parameters, 4-40, A-7
potential difference, 4-45
reaction with open thermocouple, 4-41
SM 331; AI 8 x 12 bits, 4-115
SM 331; AI 8 x 14 bits High Speed, 4-97
SM 331; AI 8 x 16 bits, 4-86
SM 331; AI 8 x RTD, 4-125
SM 331; AI 8 x TC, 4-138
smoothing of analog input values, 4-42
structure of data record 1, A-8
temperature coefficient, 4-42
temperature unit, 4-41
underflow, 4-74
wire-break, 4-73, 4-74
wire-break check, 4-40
Analog Input Module
SM 331; AI 2 x 12 bits, 4-153
SM 331; AI 8 x 16 bits, 4-77
Analog input modules
causes of errors and remedies, 4-73
diagnostic messages, 4-72
Analog input modules, SM 331,
channel-specific diagnostic data, B-6
Analog input/module, structure of data record
1, A-42
Analog input/output module
integration time, 4-44
measurement, 4-44
measuring method, 4-44
measuring range, 4-44
output range, 4-44
output type, 4-44
parameters, 4-44, A-41
SM 334; AI 4/AO 2 x 8/8 bits, 4-188
Analog Input/Output Module , SM 334; AI 4/AO
2 x 12 bits, 4-194
Analog module
assigning parameters, 4-39
behavior, 4-31
Determination of measuring error/output
error, 4-34
diagnostics, 4-71
dimension drawing, C-15
group error LED, 4-72
interrupts, 4-75
sequence of steps for commissioning, 4-8
SF LED, 4-72
supply voltage failure, 4-32
Analog output channel, conversion time, 4-37

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)