Glossary-1
Programmable Logic Controllers S7-300 Module Data
A5E00105505-03
Glossary
Address
An address denotes a specific operand or address area; examples of this are:
input I 12.1; memory word MW 25; data block DB 3.
Aggregate current
Sum of the currents of all output channels on a digital output module.
Backplane bus
The backplane bus is a serial data bus that is used by the modules to com-
municate with each other and to supply them with the voltage they require. The
interconnection of the modules is established by the bus connector.
Basic conversion time
Time for the actual encoding of a channel (integration time) plus the required
times for the internal control; i. e. after this time a channel is completely pro-
cessed.
Basic error limit
The basic error limit is the operational limit at 25 °C, referred to the rated range
of the analog module.
Basic response time
Time which an analog input/output module requires for a cycle if all channels are
released; it corresponds to the “number of all channels x basic conversion time”.
Bus
A bus is a transmission medium that interconnects several nodes. Data transmis-
sion can be serial or parallel, and be performed over electric conductors or fiber-
optic cables.
Bus segment
A bus segment is a self-contained section of a serial bus system. Bus segments
are interconnected by means of repeaters.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)