ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 197 of 545 2020-04-15
When an ongoing proactive command, requiring a user
response, is not answered before <timeout> minutes, it is
automatically aborted. In this case, the terminal response from
the module is either "ME currently unable to process
command" or, if applicable, "No response from user". In
addition, the following URC is sent on the AT interface. For
parameter meaning of the URC refer to Unsolicited fields
section.
#STN:<cmdTerminateValue>
Follows the <timeout> range.
timeout expressed in minutes
<mode>=3, the URC has the following reduced format: #STN: <cmdType>
<mode>=2, and <cmdType>=1 (REFRESH proactive command), the URC has the
following extended format:
#STN: 1,<refreshType>
<mode>=2, and <cmdType>=5 (SET UP EVENT LIST proactive command), the URC has
the following extended format:
#STN: 5[,<eventListMask>]
<mode>=2, and <cmdType>=16 (SET UP CALL proactive command), the URC has the
following extended format:
#STN: 16,<cmdDetails>,[<confirmationText>],<calledNumber>
<mode>=2, and one of the following proactive command:
<cmdType>=17 (SEND SS)
<cmdType>=18 (SEND USSD)
<cmdType>=19 (SEND SHORT MESSAGE)
<cmdType>=20 (SEND DTMF)
<cmdType>=32 (PLAY TONE)
Here are the commands that can be executed only if AT#STTA=1 has been previously set
<cmdType>=52 (RUN AT COMMAND)
<cmdType>=64 (OPEN CHANNEL)
<cmdType>=65 (CLOSE CHANNEL)
<cmdType>=66 (RECEIVE DATA)
<cmdType>=67 (SEND DATA)
the URC has the following extended format:
#STN: <cmdType>[,<alphaIdentifier>]
If <cmdType>=19 (SEND SHORT MESSAGE proactive command) fails, the #STN: 119
URC is sent to the module.