ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 242 of 545 2020-04-15
It is possible to send a concatenation of at most 10 SMs; the maximum number of chars
depends on the <dcs>:
• 2448 chars
• 2144 chars if 8-bit is used
• 1072 chars if UCS2 is used
If message sending fails for some reason, then an error code is reported.
AT+CMGS=?
Test command returns the OK result code.
To avoid malfunctions is suggested to wait for the +CMGS: <mr> or +CMS ERROR:
<err> response before issuing further commands.
To avoid malfunctions it is suggested to wait for the +CMGS: <mr> or +CMS ERROR: <err>
response before issuing further commands.
Set PDU mode
AT+CMGF=0
AT+CMGS=18
> 088128010099010259115507811020905512F90000A704F4F29C0E
+CMGS: 124
OK
Set text mode
AT+CMGF=1
AT+CSMP=17,167,0,0
AT+CMGS="01090255219",129
>TEST MESSAGE
+CMGS:125
OK