AfterRepairingorReplacingtheComponents(continued)
Fitting)(page5–7)andInstallingtheHydraulicFittings(SAEStraightThread
O-RingFittings)(page5–9).
5.Afteryoucompletetherepairs,checkthecontrollinkagesorcablesfor
properadjustment,binding,orbrokenparts.
6.Wheneverhydraulicuidhasbeendrainedfromthepumps(systemdrain,
ush,orpumpremoval/installation)itisimportanttoproperlyprimethe
hydraulicpumps,refertoPrimingtheHydraulicPumps(page5–60).
7.Afteryoudisconnectorreplaceanyhydrauliccomponents,operatethe
machinefunctionsslowlyuntiltheairisoutofthesystem;refertoCharging
theHydraulicSystem(page5–62).
8.Checkforhydraulic-uidleaks.Shutofftheengineandrepairleaksif
necessary.