OperatorAdvisories
OperatoradvisoriesareautomaticallydisplayedbytheTDMdisplay/controller
whenamachinefunctionispreventedandadditionalactionisrequired.Typically,
anadvisorycanbeeliminatedwithachangeinmachinecontrolsbytheoperator.
Forexample;iftheoperatorattemptstodrivethemachinewhentheparking
brakeisengaged,anadvisoryisidentiedontheTDMdisplay/controllerthatthe
parkingbrakeneedstobeindisengaged.Anadvisorywillnotbeloggedintoany
faultlog.Thefollowingtablelistseachadvisoryindetail.
OperatorAdvisories
Advisory
Number
AdvisoryName
Cause
InfoCenterMessage/Corrective
ActionRequired
B2004
STARTDENIEDPTOSwitchEngagedStartDenied|DisengagePTO
B005
STARTDENIED
OutOfSeatAndParking
BrakeDisengaged
StartDenied|SitdownorsetPbrake
B008
STARTDENIED
TractionPedalEngaged
StartDenied|Tractionpedaltoneutral
B200A
STARTDENIED
StarterHasBeenActive
For30Seconds
StartDenied|Keyheldtoolong
B2015
STARTDENIEDDeckSwitchEngagedStartDenied|Disengagedeckswitch
B2024
ENGINERPM
RESTRICTED
EngineOilPressureLowEngineRPMRestricted|CheckOil
B2027
ENGINESHUTDOWN
EngineTooHot
EngineShutdown|Checkcoolingsystem
B2028
ENGINEDERATE
EngineTooHot
EngineDerate|Checkcoolingsystem
B2029
ENGINERPM
RESTRICTED
OutOfSeatEngineShutdown|Mustbeseated
B202F
ENGINESHUTDOWN
ParkingBrakeEngaged
EngineShutdown|Disengageparkingbrake
B2409
DECKLOWER
DENIED
OutOfSeatLowerDenied|Mustbeseated
B2422
DECKRAISEDENIED
EngineNotRunning
RaiseDenied|Startengine
B2424
DECKRAISEDENIED
OutOfSeatAndParking
BrakeDisengaged
RaiseDenied|SitdownorsetPbrake
B2504
PTODENIEDEngineOilPressureLowPTODenied|Checkoil
B2507
PTODENIED
Enginetoohot
PTODenied|Checkcoolingsystem
B2509
PTODENIEDOutofseatPTODenied|Mustbeseated
B250A
PTODENIED
NoDecksFloating
PTODenied|Lowerdecks
B250B
PTODENIED
EngineNotRunning
PTODenied|Startengine
B2705
INVALIDMODELOR
SERIALNUMBER
UnknownCause
InvalidModelorSerialNumber|
ReprogramSoftware
B2800
REGENSTATUSRegenCompleteRegenComplete
B2801
REGENREQUIRED
InhibitActiveRegenRequired.RemoveInhibit
B2802
REGENREQUIRED
LowExhaustTemp
SetEnginetofullthrottle.RegenRequired.
B2804
PARKEDREGEN
REQUIRED
EngineRequested
ParkedRegenRequired.SeeServiceMenu.
B2805
PTODISABLED
ParkedRegenRequired
ParkedRegenRequired.PTOdenied.
B2807
PTODISABLED
RecoveryRegenRequired
RecoveryRegenRequired.PTOdenied.
B280A
REGENSTATUS
RegenFailedRegenFailed
Groundsmaster
®
3200,3300and3310
Page3–3
Troubleshooting:CuttingUnit(orattachment)Problems
19240SLRevA