Regeneration(continued)
Typesofregenerationthatareperformedmanually(whilethemachineis
stationary)
Type
Conditions
Description
Parked
Occurswhenexhaust
backpressureinthe
DPFincreasesdueto
continuedsootbuildup.
Mayoccurbecausethe
InfoCenterwassetto
inhibitresetregeneration
andmachineoperation
continued,addingmore
soottotheDPFaftera
resetregenerationwas
requested.
Maybecausedby
prolongedoperationat
lowenginespeed,low
engineload,ortheuseof
incorrectfuelorengineoil.
Canbeinitiatedwhen
promptedbytheengine
ECUormanuallyaftera
minimumof50hoursof
engineoperation.
Thedisplayscreendisplays
thestationaryregenerationicon.
Manuallyinitiateaparkedregeneration
assoonaspossible.Aparked
regenerationwilltakeapproximately
30to60minutesandshouldnotbe
startedwithlessthan1/4tankoffuel.
Themachinemustremainstationary
(cannotbeoperated)duringtheentire
parkedregenerationprocess.
Recovery
Occurswhenexhaust
backpressureintheDPF
increasesduetosoot
buildupreachingacritical
level.
Mayoccurbecause
parkedregeneration
requestswereignored
andmachineoperation
continued,addingmore
soottotheDPFaftera
parkedregenerationwas
requested.
Canonlybeinitiatedwhen
promptedbytheengine
ECU.
Thedisplayscreendisplays
thestationaryregenerationicon.
Manuallyinitiatearecovery
regenerationassoonaspossible.
Arecoveryregenerationwilltake
approximately3hoursandshouldnot
bestartedwithlessthan1/2tankoffuel.
Themachinemustremainstationary
(cannotbeoperated)duringtheentire
recoveryregenerationprocess.
RefertothetractionunitOperator’sManualforadditionalDPFregeneration
information,andinstructionsforusingtheInfoCenterDPFRegenerationMenus.
SootAccumulation
Ifthetypesofregenerationsthatareperformedautomatically(whilethemachine
isoperating)arenotallowedtocomplete,sootwillcontinuetoaccumulatein
thesootlter.Whenenoughsootaccumulates,theengineECUwillgenerate
anenginefaulttopromptaparkedorrecoveryregeneration.Inadditiontoan
enginefaultappearingonTDMdisplay/controllerscreen,theengineoutput
powerwillbereduced.
AshAccumulation
Ashisaresultoftheregenerationprocesses.Thelighterashisdischarged
throughtheexhaustsystem,whiletheheavierashcollectsinthesootlter.
Whenenoughashaccumulatesinthesootlter,theengineECUwillgeneratean
Groundsmaster
®
3200,3300and3310
Page4–7
Engine:GeneralInformation
19240SLRevA