4-20 Phaser 7750 Printer Service Manual
The +5 VDC Interlock Circuit 
The 5 VDC interlock circuit runs from the 5 VDC LVPS to the L/H door switch, then 
to the engine control interface board, out to the R/H door switch, back to the engine 
control interface board, out to the front door, through the coil of the LD power relay 
and back to the 5 VDC LVPS. This circuit helps identify which door has interrupted 
the 24 VDC circuit.
If the circuit is complete, LD power relay activates, and 5 VDC is sent to the waste 
cartridge installed interlock switch and through all four imaging unit connectors and 
to the engine control interface board. This signal merely confirms that all imaging 
units are installed. Individual missing components are identified at power-up or when 
a door is closed (completing the 24 VDC circuit) and the engine control board 
interrogates the imaging unit NVRAM. If the imaging units are present, then the 
waste cartridge is missing by default.
1. With all doors closed and printer power on, check for +5 VDC between P536-4 
of the engine control interface board and frame ground.   If not present, check the 
LD relay and the LH cover interlock switch.
2. Check for +5 VDC between P631-3 of the engine control interface board and 
frame ground. If not present, check the front cover interlock switch.
3. Check for +5 VDC between J568-5 (top pin) of the LD power relay and frame 
ground. If not present, check the RH cover interlock switch.
4. Check for +5 VDC between J400-6 of the engine control interface board and 
frame ground. If not present, check the LD power relay, and the circuit through 
the waste cartridge sensor and the four imaging unit connectors.
5. If +5 VDC is present, then replace the engine control board.