Adjustments and Calibrations 6-7
RegiCon #1 Fine Skew Adjustment
This process uses sensors to examine the RegiCon image on the belt and report what 
adjustments need to be made. A side effect of this test is that horizontal and vertical 
alignments are automatically done (if the test passed).
The data output presents the skew screw adjustment values (some number of "clicks" 
of the screw, either CW or CCW direction). Values less than 5 or so are "noise" and 
should not need to be adjusted. 
1. From the Hidden Service menu, highlight the RegiCon Setup Cycle menu 
and press OK.
2. The first time any RegiCon test is requested, the pages used to perform the test 
must be created, so there is a short delay. During this time the front panel displays 
“Processing Data - Please Wait”
3. Highlight Do #1 Fine Skew Setup and press OK. The front panel now 
displays: Testing - Please Wait.
4. Wait until the test results are displayed as follows:
Note
Only 5 lines will be displayed at a time under the Information header. Use 
the arrow buttons to scroll down or up as required to see the rest of the data.
Note
If the block counts are not the same number as presented here, the printer has 
a print-quality problem. See "Streaks in Direction of Paper Travel" on 
page 5-17 to resolve the print-quality problems before proceeding further 
with RegiCon.
5. If an adjustment is needed, adjust by the amounts displayed on the front panel 
until all clicks displayed are 5 or less.
Note
If RegiCon #1 Fine Skew test fails, see "RegiCon #4 Coarse Skew 
Adjustment" on page 6-10.
Fine Skew Setup
Yellow 1 Click CW
Min B Blocks: 4
Min A Blocks: 24
Passed 
Magenta 7 Clicks CCW
Cyan 7 Clicks CW
Black 7 Clicks CCW