10-34 Phaser 7750 Printer Service Manual
DC Power Generation 3.3 VDC
1
2
1.2
16.1
7.11
7.1
ALL
ALL
ALL
ON/
OFF
ALL
1.1B
1.1B
MCU +3.3V
ENABLE SIGNAL
POWER ON ACH
(TO +3.3V LVPS)
POWER ON ACH
(TO +3.3V LVPS)
1.3 DC POWER GENERATION (3.3VDC)
+3.3V LOW VOLTAGE
POWER SUPPLY 1 PL9.1
J15A
BLK
WHT
GRN
+3.3VDC
POWER
GENERAT-
ION
12
6
9
4
8
11
1
1
2
3
4
8
10
11
1
3
5
7
VIO
GRY
VIO
GRY
VIO
GRY
VIO
GRY
GRY
GRY
GRY
GRY
GRY
GRY
VIO
VIO
VIO
VIO
VIO
P510
P510
P510 P668
J668 J555
J510 J300
J400
VIO
3
5
T3
B8
B9
B6
B5
B7
B11
ESS PWB
PL13.1
+3.3VDC-1
+3.3VDC
+3.3VDC
+3.3VDC-2
MCU PWB
PL13.1
1/F
PWB
P19.1
P/J410
32
56
B3
B10
J532
YEL
YEL
J536
+3.3VDC
(MSI SIZE SENSOR)
+3.3VDC TRAY 1
SIZE SENSOR
WITH 3TM ATTM (FX ONLY)
TRAY
MODULE
PWB
PL15.9/ 16.15
55
6
5
66
DC COM
1
2
Wiring in MCU PWB
Short Circuit Protection (Overcurrent Protection)
When +3.3V DC circuit is shorted, the output droops.
The output auto-recovers in 10 sec. after recovery from the short circuit.
Overvoltage Protection
When +3.3V DC output reaches +4-+5V DC, the output is cut
off. The output recovers at power on 60 sec after power off.
NOTE:
7750-264