9-44
SELF-DIAGNOSTIC FUNCTION AND DIAGNOSTIC CODE TABLE
P0117
P0118
[P0117] Coolant
temperature sensor:
ground short circuit
detected.
[P0118] Coolant
temperature sensor:
open or power short
circuit detected.
[P0117] Low voltage
of the coolant tem-
perature sensor cir-
cuit (0.1 V or less)
[P0118] High volt-
age of the coolant
temperature sensor
circuit (4.9 V or
more)
• Defective coupler
between coolant
temperature sen-
sor and ECU.
• Open or short cir-
cuit in wire har-
ness between
coolant tempera-
ture sensor and
ECU.
• Improperly in-
stalled coolant
temperature sen-
sor.
• Defective coolant
temperature sen-
sor.
• Malfunction in
ECU.
Engine is difficult to
start.
Increased exhaust
emissions.
Engine idling speed
is unstable.
The radiator fan mo-
tor relay is on only
when the vehicle is
traveling at low
speeds.
O
2
feedback is not
carried out.
ISC feedback is not
carried out.
ISC learning is not
carried out.
The coolant tem-
perature is fixed to
60 [ï‚°C].
Cruise control sys-
tem cannot be oper-
ated.
DTC Item
Probable cause of
malfunction
Vehicle symptom
Fail-safe system
operation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yamaha TMAX TECH MAX 2020 and is the answer not in the manual?

Yamaha TMAX TECH MAX 2020 Specifications

General IconGeneral
BrandYamaha
ModelTMAX TECH MAX 2020
CategoryMotorcycle
LanguageEnglish

Related product manuals