8 System Setup
8.2 Setting the Second Home Position (Check Point)
8-19
182582-1CD
182582-1CD
MH900, DX200 Controller
3. Press the [PAGE], or select [PAGE] to display the selection window for
the control group.
– When there are two or more group axes, select the group axes to
which the second home position is to be specified.
4. Press [FWD].
– TCP moves to the second home position. The robot moving speed is
set as selected manual speed.
5. Select {DATA} under the menu.
6. Select {CONFIRM POSITION}.
– A message “Home position checked” appears.
– Pulse data of the second home position and current pulse data are
compared. If the compared error is in allowed range, playback
operation can be done.
– If the error is beyond the allowed range, the alarm occurs again.