9-1
182582-1CD
182582-1CD
9 System Backup
9.1 System Backup with Controller
MH900, DX200 Controller
9 System Backup
For the controller, the system data can be collectively backed up in
advance so that the data can be immediately loaded and restored in case
of an unexpected trouble such as data loss.
9.1 System Backup with Controller
For the controller, two types of collective backup are available: CMOS.BIN
and CMOSBK.BIN.
9.1.1 Function Types of Data
9.1.1.1 CMOS.BIN
For the normal backup, use this data.
Save: Perform in the normal or maintenance mode.
Load: Perform in the maintenance mode.
(the management mode or higher mode)
The loading/saving procedures in the maintenance mode,
refer to chapter 9.2 “Backup by CMOS.BIN” at page 9-4.
As for saving in the normal mode, refer to DX200 OPERATOR’S
MANUAL section 7.3.0.2 “Saving Data”.
Target Area: All areas of the internally stored data.
(Note that the monitoring time is not loaded.)
9.1.1.2 CMOSBK.BIN
This data is used in the automatic backup function.
Save: Saves with the preset conditions in the normal mode.
Load: Perform for the system restoration in the maintenance mode
(the management mode or higher mode)
For details, refer to chapter 9.3 “Automatic Backup Function” at page 9-8.
Target Area: All areas of the internally stored data.
(Note that the monitoring time is not loaded.)
9.1.2 Device
For the backup of the controller system, the CompactFlash or the USB
memory is used. (The USB slot of the programming pendant is not
available in the automatic backup function.)
The following tables show the recommended CompactFlash and USB
memory.
<Recommended CompactFlash>
No. Manufacturer Model Remarks
1 Hagiwara Solutions MCF10P-256MS-YE 256MB
2 Hagiwara Solutions MCF10P-512MS 512MB
3 Hagiwara Solutions MCF10P-A01GS 1GB
4 Hagiwara Solutions MCF10P-A02GS 2GB