3 Installation
3.2 Place of Installation
MH900, DX200 Controller
3.2 Place of Installation
The controller requires the following conditions for installation:
• Ambient temperature:
– During Operation: 0 to 45C (32 to 113F) during operation
– During Transportation and Maintenance -10 to 60C(14 to 140F)
–Temperature Change: 0.3C per minute or less
• Humidity: 10 to 90% RH with no condensation
• Only a small amount of dirt, dust, cutting oil, organic solvent, oil
fume, water, salt, etc. in the place
(Especially, avoid adhesion of chemicals, cutting oil including
coolant, rust preventive oil, organic solvent, etc. to the programming
pendant.)
• Free from flammable or corrosive liquid, gas, etc.
• Free from excessive shock, vibration, etc. (vibration: 0.5G or less)
• Free from large electrical noise
(An electrical noise source such as a TIG welding device must not
be placed close to the controller.)
• Free from excessive microwaves, ultraviolet rays, X-rays, or
radiation
• Altitude: 1000m or less
(To use the controller at the altitude over 1000m, calculate the
maximum ambient temperature by decreasing it by 1% per 100m.
The maximum allowable altitude is 2000m. When the altitude is
2000m, the maximum ambient temperature during operation is
40.5C.
If the external electric noise applies, the alarm occurs and
the manipulator may stop.
When the alarm occurs and the manipulator stops, refer to
controller maintenance manual and reset the alarm.