9 System Backup
9.5 Error List
MH900, DX200 Controller
9.5 Error List
9.5.1 Error Contents
Error
No.
Data Message Cause
0770 * The robot or the station is in
motion.
The automatic backup would
not work when the robot or a
manipulator is in motion.
3390 File not found The file to be loaded no longer
exists.
3430 * I/O error on the drive The capacity of the
CompactFlash is 128MB.
Change the CompactFlash to
256MB.
3460 * Cannot backup CompactFlash
1 Insufficient capacity of the
CompactFlash
2 Cannot access the
CompactFlash
3501 * Confirm the status of
CompactFlash.
Cannot access the
CompactFlash
3550 * The automatic backup is
executed. Try it later.
The automatic backup window
cannot be called to display while
the automatic backup is being
processed.
3551 * The automatic backup is
executed. Arrange the file after
it is finished.
The file arrangement cannot be
operated during the automatic
backup operation.
3560 * Failed to re-arrange the backup
file.
Failed to re-arrange the backup
file for another reason than the
access to CompactFlash.
3580 * Accessing to backup file. Try it
later.
To display another window and
then display the automatic
backup window again after
“ARRANGE” operation,
“ARRANGE” process should be
completely finished.
3581 * Accessing to backup file. Try
“ARRANGE” operation later.
The previous “ARRANGE”
process should be completely
finished to perform the next
“ARRANGE” operation.