EasyManua.ls Logo

YASKAWA DX200 - 14.6.11 Emergency Stop Output

YASKAWA DX200
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14-32
182582-1CD
182582-1CD
14 Description of Units and Circuit Boards
14.6Machine Safety Terminal Block Circuit Board (JANCD-YFC22-E)
MH900, DX200 Controller
14.6.11 Emergency Stop Output
Outputs the contact output terminals for both emergency stop buttons on
the programming pendant and on the front door.
These contact outputs are always valid regardless of the DX200 main
power supply status ON or OFF. (Status output signal: normally closed
contact)
Fig. 14-23: Output of Emergency Button
Do not use the emergency stop button with 24 VAC, 0.5 A or more.
Failure to observe this instruction may result in damage to equipment.
57
58
CN219
PBESP3-
PBESP3+
PBESP3-
PBESP3+
59
60PBESP4-
PBESP4+
PBESP4-
PBESP4+
DX200
53
54PPESP3-
PPESP3+
PPESP3-
PPESP3+
55
56PPESP4-
PPESP4+
PPESP4-
PPESP4+
Emergency
stop button
Emergency
stop button
Front door of DX200
Programming pendant
Machine safety terminal
block circuit board
(JANCD-YFC22-E)
507 of 552

Table of Contents

Other manuals for YASKAWA DX200

Related product manuals