14 Description of Units and Circuit Boards
14.6Machine Safety Terminal Block Circuit Board (JANCD-YFC22-E)
14-31
182582-1CD
182582-1CD
MH900, DX200 Controller
The following figure shows the external axis overrun wiring of the factory
default setting when the external axes are connected to the DX200.
Please refer to the following figure to connect the external axes overrun
signal to wire in the another route. On that occasion, confirm the external
axes overrun setting to connect. (Refer to section 12.3.1.2 “Connection
Setting" on page 12-20. )
Fig. 14-22: Connection for External Axis Overrun (Multiple Lines)
41
42
43
44
CN219
OT2_1-
DX200
OT2_2-
OT2_1+
OT2_2+
45
46
47
48
OT3_1-
OT3_2-
OT3_1+
OT3_2+
49
50
51
52
OT4_1-
OT4_2-
OT4_1+
OT4_2+
External axis overrun
The first line
The second line
The third line
External axis overrun
External axis overrun
Turn ON/OFF
at the same time
Turn ON/OFF
at the same time
Turn ON/OFF
at the same time
Machine safety terminal
block circuit board
(JANCD-YFC22-E)