9 System Backup
9.2 Backup by CMOS.BIN
9-4
182582-1CD
182582-1CD
MH900, DX200 Controller
9.2 Backup by CMOS.BIN
Perform the backup by CMOS.BIN in the normal or maintenance mode.
The chart below shows the availability of CMOS save/CMOS load in each
security mode in the maintenance mode.
9.2.1 CMOS.BIN Save
Follow the procedures below to save CMOS.BIN in the maintenance
mode.
1. Turn ON the controller power supply while pressing [MAIN MENU].
2. Insert a CompactFlash into the CompactFlash slot on the
programming pendant.
– when USB memory is used instead of CompactFlash, mount USB
memory and select one among “USB: PENDANT”, “USB1:
CONTROLLER” and “USB2: CONTROLLER” in the {DEVICE}.
3. Select {FD/PC CARD} under the main menu.
– The sub menu appears.
Security CMOS Save CMOS Load
Operation Mode
ഊ X
Editing Mode
ഊ X
Management Mode
ഊഊ
Safety Mode ഊഊ