8 System Setup
8.21Preventive Maintenance Function
8-179
182582-1CD
182582-1CD
MH900, DX200 Controller
8.21.3 Inspection Notice Function
The inspection notice function turns the notice signal ON and displays the
message when the inspection time has come.
Perform the inspection by the authorized personnel or Yaskawa
representative (the list on the back cover) when the notice signal is turned
ON.
8.21.3.1 Inspection Signal
Set the universal output signal for the inspection time as the following
procedures.
1. Change the security mode to the management mode.
2. Select {=RM} in the main menu.
3. Select {=INSPECTION NOTICE}.
– The inspection notice window appears.
4. Select {Display} in the main menu.
– {=SETUP CONDITION} is displayed in the pull down menu.
5. Select {=SETUP CONDITION}.
– {=SETUP CONDITION} window appears.