EasyManua.ls Logo

YASKAWA DX200 - 14.6.6 External Hold

YASKAWA DX200
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14-26
182582-1CD
182582-1CD
14 Description of Units and Circuit Boards
14.6Machine Safety Terminal Block Circuit Board (JANCD-YFC22-E)
MH900, DX200 Controller
14.6.6 External Hold
This signal is used to connect the temporary stop switch of an external
device. If the signal is input, the job is stopped. While the signal is input,
starting and axis operations are disabled.
Fig. 14-17: Connection for External Hold
Jumper cables are installed at the factory. Be sure to remove the
jumper cables before using.
If the cables are not removed, injury or damage to machinery may
result and the external emergency stop will not work even if the signal
is input.
19
20
CN219
DX200
EXHOLD-
EXHOLD+
Remove the jumper cable
External Hold
Machine safety terminal
block circuit board
(JANCD-YFC22-E)