EasyManua.ls Logo

YASKAWA DX200 - 14.6.14 Connection for Direct-in

YASKAWA DX200
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 Description of Units and Circuit Boards
14.6Machine Safety Terminal Block Circuit Board (JANCD-YFC22-E)
14-35
182582-1CD
182582-1CD
MH900, DX200 Controller
14.6.14 Connection for Direct-in
Direct-in (Servo) 1 to 6
This signal is used to input a responsive signal in search functions.
Fig. 14-26: Connection for Direct-in (Servo) 1 to 6
86
87
88
89
90
91
85
81,82
83,84
CN219
024V2
+24V2
AXDIN1
AXDIN2
AXDIN3
AXDIN4
AXDIN5
AXDIN6
AXDIN_COM
86
87
88
89
90
91
85
81,82
83,84
CN219
024V2
+24V2
AXDIN1
AXDIN2
AXDIN3
AXDIN4
AXDIN5
AXDIN6
AXDIN_COM
Direct-in (Servo) 1
Direct-in (Servo) 2
Direct-in (Servo) 3
Direct-in (Servo) 4
Direct-in (Servo) 5
Direct-in (Servo) 6
Major Axes Control
Circuit Board
(SRDA-EAXA21A)
Connect the jumper cable.
Connect the jumper cable.
The part of wiring is that if there is a slave for the coordinated control side
major axes control circuit board (SRDA-EAXA21A).
Major Axes Control
Circuit Board
(SRDA-EAXA21A)
Machine safety terminal
block circuit board
(JANCD-YFC22-E)
Machine safety terminal
block circuit board
(JANCD-YFC22-E)
510 of 552