EasyManua.ls Logo

YASKAWA DX200 - 8.24 Robot Stop Factor Monitor Function; 8.24.1 Outline

YASKAWA DX200
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-282
182582-1CD
182582-1CD
8 System Setup
8.24Robot Stop Factor Monitor Function
MH900, DX200 Controller
8.24 Robot Stop Factor Monitor Function
8.24.1 Outline
The robot stop factor monitor function is a function to detect a robot stop,
which is caused by the servo OFF or the hold and so on. The factors,
which caused to stop the robot, are stored in chronological order and
displayed on the screen.
8.24.1.1 The Robot Stop Factor
This function detects the servo OFF status caused by the machine safety
circuit board instructions or the main CPU instructions and the hold status
caused by programing pendant operations or signals. The detection items
are described as follows.
Table 8-1: The List of the Servo OFF Factors by Main CPU Instructions
Displayed Item Secondary Indication
EX.SERVO OFF1 (HOLD STOP) System input signal number
(#40065)
EX.SERVO OFF2 (CATEGORY0 STOP) System input signal number
(#40066)
EX.SERVO OFF3 (CATEGORY1 STOP) System input signal number
(#40064)
TEACH -> PLAY MODE CHANGE None
PLAY -> TEACH MODE CHANGE None
MAIN CPU ALARM None
PARAMETER CHANGE None
INST SVOFF None
COMMAND SVON None
HOME POSITIONING CHANGE None
DATA FALSE RESTORE None
TOOL FILE CHANGE None
TOOL CALIBLATION None
ENCODER RESET None
ROBOT DETACHMENT None
GROUND FAULT (BRAKE LINE) None
MANUAL FULL SPEED None
SERVO OFF QUE None
SERVO ON ERROR None
SERVO OFF ERROR None