8 System Setup
8.15Numeric Key Customize Function
8-131
182582-1CD
182582-1CD
MH900, DX200 Controller
8.15.3 Allocation of I/O Control Instructions
In key allocation (SIM), output control instructions can be allocated to the
numeric keys that have been allocated one of the following I/O controls
with key allocation (EACH).
1. Allocation of I/O control instruction.
– Allocate the I/O control instruction with key allocation (SIM) following
the forementioned procedure.
2. Move the cursor to the “FUNCTION” of the key that has been allocated
with I/O control with key allocation (SIM) and press [SELECT].
– Selection list appears.
Function Output Control Instruction allowed to be
Allocated
Alternate output allocation DOUT OT# (No.) ON
Momentary output allocation
Pulse output allocation PULSE OT# (No.) T = output time
Group output allocation (4-bit) DOUT OGH (No.) output value
Group output allocation (8-bit) DOUT OG# (No.) output value
Analog output allocation AOUT AO# (No.) output voltage value