EasyManua.ls Logo

YASKAWA DX200 - 8.16 Changing the Output Status

YASKAWA DX200
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-134
182582-1CD
182582-1CD
8 System Setup
8.16Changing the Output Status
MH900, DX200 Controller
8.16 Changing the Output Status
The status of external output signals can be changed from the
programming pendant by using either of the following two methods.
• On the user output status window
• On the RELAY ON window
The method that uses the RELAY ON window, which is described here,
simplifies the operation for changing the status of signals that are used
frequently.
1. Select {IN/OUT} under the main menu.
2. Select {RELAY ON}.
The RELAY ON window appears.
3. Select the desired signal to change the output status.
Select the status ( or ) of the desired signal.
A maximum of 64 output signals can be shown on the
RELAY ON window and they must be set in advance to
parameters S4C327 to S4C390. If they are not set, the sub
menu in the RELAY ON window will not be displayed.
221 of 552