8-180
182582-1CD
182582-1CD
8 System Setup
8.21Preventive Maintenance Function
MH900, DX200 Controller
6. Move the cursor over the “=INSPECTION SIGNAL”, and select.
– It becomes the numeric value input status.
7. Enter the universal output number.
8.21.3.2 The Inspection Notice Window
1. Select {=RM} in the main menu.
2. Select {=INSPECTION NOTICE}.
– The inspection notice window appears.
Each item on the screen represents the following description.
=TIME TO INSPECTION
The rest of the time to inspection is displayed. When the servo power is
turned ON, it calculates the subtraction automatically. When this item
become “0”, the inspection notice signal is turned ON, and the message is
displayed.
1