8-162
182582-1CD
182582-1CD
8 System Setup
8.20Encoder Back-up Error Recovery Function
MH900, DX200 Controller
10. Select {YES}.
The absolute data of the selected axis is recovered.
Select {NO} to cancel the operation.
11. Select the current position.
To display the current position window, refer to DX200
MAINTENANCE MANUAL section 7.8.1 “Current Position Window”.
12. Confirm the current position.
Confirm the recovered current position, and modify the followings
depending on its values.
(1) The pulse number is approximately “0”.
• Recovered normally.
(2) The pulse number is approximately “4096”.
• Move the recovered axis to the 4096 pulse position, and register
the individual axis to calibrate the home position.
(3) The pulse number is approximately “-4096”.
Move the recovered axis to the -4096 pulse position, and register
the individual axis to calibrate the home position.
As for the registering the individual axis, refer to section 8.1.2
“Calibrating Operation” on page 8-5.
249 of 552