8-174
182582-1CD
182582-1CD
8 System Setup
8.21Preventive Maintenance Function
MH900, DX200 Controller
Invalidate the Warning Output Signal
Able to invalidate for each axis. Invalidate the warning output signal by the
following procedures, in the case of the speed reducer seems to operate
normally even though the warning output signal is turned ON.
1. Select {=RM} in the main menu.
The sub menu appears.
2. Select {=RM(REDUCER)}.
The lifetime calculation window appears.
3. Select {Display}.
The pull down menu appears.
4. Select {=TORQUE MONITOR}.
The torque monitor window appears.
Move the cursor over the “=WARNING” of the desired axis to invalidate,
and press [Select]. [Invalid] and [Valid] will alternate each time when
pressing the [Select].
Graph Display
Able to confirm the variation by a graph after the measurement. The graph
is updated every 24 hours automatically. The measured value and
changes of the variation can be displayed on the programming pendant.
Thus, able to confirm the changes of the torque visually. Use the graph
display as the one of the methods to determine the duration of life for the
speed reducer.
The graph can be displayed by the following procedures.
1. Select {=RM} in the main menu.
2. Select {=RM(REDUCER)}.
3. Select {Display}.
The pull down menu appears.
261 of 552