8 System Setup
8.23Safety Logic Circuit
8-203
182582-1CD
182582-1CD
MH900, DX200 Controller
8.23.2.2 Allocating the Machine Safety Signal
1. Displaying the window.
– Select {M-SAFETY SIGNAL ALLOC} from {SAFETY FUNC.} in the
main menu.
2. Set up the universal safety signal.
– In the controller, the two points of the universal safety input signal
and the two points of the universal safety output signal are present
from I/O board (type:YSF22 ჱ -E), and these signals can be used at
the safety logic circuit.
Set the “USE” for the input and output signal(s) to use.
After the setting, the status changes from “DONE” to “NOT DONE”.
The “WRITE” button is displayed on the left down corner of the
screen.