8-254
182582-1CD
182582-1CD
8 System Setup
8.23Safety Logic Circuit
MH900, DX200 Controller
3. When #1 GSIN1 signal and #1 GSIN2 are simultaneously turned ON,
#1 GSOUT1 is ON for one second.
4. When #1 GSIN1 signal and #1 GSIN2 are not simultaneously turned
ON, #1 GSOUT1 remains OFF.
#1 GSIN1
#1 GSOUT1
1sec
#1 GSIN2
#1 GSIN1
#1 GSOUT1
#1 GSIN2
341 of 552