12 Modification of System Configuration
12.3Addition of Base and Station Axes
12-30
182582-1CD
182582-1CD
MH900, DX200 Controller
3. Select desired type in the type list.
– After the type selection, the window returns to CONNECT window.
– Select “UNIV” (universal) when using a mechanism other than the
registered type (such as a servo track) as a station axis. When
“UNIV” is selected, interpolation motion (linear, circular, etc.) is not
supported.
12.3.2.2 Connection Setting
In the CONNECT window, it is specified that each axis of each control
group is connected to which connector of the SERVO board, which break
of the contactor unit, which converter, and which overrun signal.
1. Confirm the type of each control group in the CONNECT window.
2. Connection status of each control group is displayed. Select the
connection item of desired control group.
– The settable items are displayed.
– Select an item to change the setting. Select {Cancel} to return to the
CONNECT window.
[CONNECT (STO) window]
STATION 1ST AXIS
TURN-1