12 Modification of System Configuration
12.3Addition of Base and Station Axes
12-32
182582-1CD
182582-1CD
MH900, DX200 Controller
– In this example, S1 (Station) is connected in the following manner:
3. An overrun signal is allocated to a control group. Therefore, when an
overrun alarm occurs, the subcode is indicated by the control group.
However, select “NOT CONNECT” if an overrun switch is not installed
to the control group or the allocation of the external axis overrun signal
is not needed.
Regarding the connection of the external axis overrun signal, refer to
section 14.7.1 “Universal I/O Circuit Board (JANCD-YIO21-E)” on
page 14-37.
4. Select a desired item.
5. Press [ENTER] in the CONNECT window.
– The setting in the CONNECT window is completed and the window
moves to the AXES CONFIG window.
1st axis SERVO Board (SV #1), Connector (7CN),
Contactor Unit (TU #1), break Connector (BRK7),
Converter (CV #2)
2nd axis SERVO Board (SV #1), Connector (8CN),
Contactor Unit (TU #1), break Connector (BRK8),
Converter (CV #3)
Overrun (OT2)